Job # 269
Initial Screen taken after 2 hrs of flushing

-Pipe Type: Stainless Steel
-Pipe Diameter: 6 inch
-Length of pipe: 190-220 Ft
-Horizontal and vertical piping
-Reynolds Number: over 8250
-Oil Temp: 140F to 160F
-Oil type: 32 weight synthetic
-ISO Code Initial: 24/22/19 (1 hr into flush)
Notes: The debris found in the initial screen was contaminated with sand, gravel, plastic, 
fibres, all this debris was caked onto the screen aproximately 1/8 thick.  

Job #269
Final Screen taken after 24 hrs of flushing

-Pipe Type: Stainless Steel
-Pipe Diameter: 6 inch
-Length of pipe: 190-220 Ft
-Horizontal and vertical piping
-Reynolds Number: over 8250
-Oil Temp: 140F to 160F
-Oil type: 32 weight synthetic 
-ISO Code Final Results: 9/8/7 (24 hrs of flushing)

Job # 326 
Initial Screen taken after 2 hrs of flushing
-Pipe Type: Stainless Steel
-Pipe Diameter: 3 inch
-Length of pipe: 150-170 Ft
-Horizontal and vertical piping
-Reynolds Number: over 10,500
-Oil Temp: 140F to 160F
-Oil type: 32 weight synthetic
-ISO Code Initial: 22/21/18 (1 hr into flush)
Notes: System was contaminated with stainless cuttings, plastic, rocks, silt, sand, sunflower seeds, and welding slag debris.

Job #326 
Final Screen taken after 24 hrs of flushing
-Pipe Type: Stainless Steel
-Pipe Diameter: 3 inch
-Length of pipe: 150-170 Ft
-Horizontal and vertical piping
-Reynolds Number: over 10,500
-Oil Temp: 140F to 160F
-Oil type: 32 weight synthetic
-ISO Code Final Results: 10/9/7 (24 hrs of flushing)

Job #990
Rust Inside a tank inspected and cleaned
-This Tank was Highly Contaminated with Water resulting in 4 Litres of Rust

Job #528
Wear Metal Shavings After 2 hrs of Flushing
3" pipe
-New Construction

Job #521
Wear Metal Removed from 3" Stainless pipe after 2 hrs of Flushing 
- This Pipe was New and Supposedly Pigged!!
- Over 2 litres of metal was removed.